UNIRAIL S 50264-3-2 300V MMS FR

Naziv
Koda izdelka
Testna napetost
Nazivni presek vodnika (mm2)
Nazivni zunanji premer
Cena
Količina
+
UNIRAIL S 50264-3-2 300V MMS FR 2X1,5
15382157
2 kV
1.5 mm2
8.1 mm
3,55 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 3X0,75
15382152
2 kV
0.75 mm2
7.3 mm
3,17 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 2X2,5
15382158
2 kV
2.5 mm2
9.1 mm
4,36 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 6X1
15382156
2 kV
1 mm2
10.0 mm
5,62 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 4X1
15382155
2 kV
1 mm2
8.3 mm
4,25 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 3X1
15382154
2 kV
1 mm2
7.6 mm
3,44 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 2X1
15382153
2 kV
1 mm2
7.0 mm
2,94 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 4X0,5
15382151
2 kV
0.5 mm2
7.3 mm
3,24 €
Rok dobave sporočimo po obdelavi naročila.
+
UNIRAIL S 50264-3-2 300V MMS FR 2X0,5
15382150
2 kV
0.5 mm2
6.3 mm
2,11 €
Rok dobave sporočimo po obdelavi naročila.

Benefits

  • Space-saving due to reduced wall thicknesses.
  • Insulation integrity for up to 120 minutes under the effect of fire (classification PH120 according to DIN EN 50200). Guarantees functional integrity and the power supply in the event of an emergency.
  • Ideal protection against electromagnetic interference thanks to copper screening braiding with a high degree of coverage.
  • The cross-linked insulation and sheath materials promote longevity at high temperatures or with a high current load, and provide high dielectric strength.
  • Compliant with standards for use in railway vehicles: fire safety and cable design requirements in accordance with DIN EN 50264-3-2, type MMS; fire behaviour in accordance with DIN EN 45545-2, hazard level HL3.

Applications

  • The cross-linked polymer compound is highly resistant to oils, fuels, alkalis and acids.
  • For wiring safety-related components in railway vehicles.
  • Typical application areas are emergency power circuits for alarm, lighting and communication purposes, which must maintain their function for a certain period of time in the event of a fire.
  • For use in railway vehicles, for fixed installation and applications where limited movement is to be expected.
  • Especially for environments where electromagnetic compatibility (EMC) is required.
  • Can be used in dry, damp and, especially, harsh and oily environments.

Documentation

Notes

  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.

KONTAKTIRAJTE NAS

Pošljite nam E-mail ali pa nas pokličite na +386 2 42 13 550